MPTS™ Attributes ... all in 1-unit
CAPACITY RELEASE ... equip for less power usage or sell excess power.
-
Add ±20% electricity equipment without additional transformer power
-
Size backup power generation down by ±20% e.g., 1,000KW → 800K
-
Or sell ±20% generated electricity power back to the utility power grid
-
With MPTS, a 20KW solar power now sends 24KW to the electric grid
![image.png](https://static.wixstatic.com/media/c78f87_d3d5e0bd99b34a1982c0e4692aceb77b~mv2.png/v1/fill/w_218,h_149,al_c,lg_1,q_85,enc_avif,quality_auto/image.png)
![image.png](https://static.wixstatic.com/media/c78f87_e8641c6e27624e54a0f7fc13b2ccfd35~mv2.png/v1/fill/w_49,h_149,al_c,lg_1,q_85,enc_avif,quality_auto/image.png)
![image.png](https://static.wixstatic.com/media/c78f87_96ed7712c9d144ca8e33bbf23d3a3cc3~mv2.png/v1/fill/w_190,h_118,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
![image.png](https://static.wixstatic.com/media/c78f87_2236451cf47f40b19521770006d49e47~mv2.png/v1/fill/w_218,h_149,al_c,lg_1,q_85,enc_avif,quality_auto/image.png)
POWER QUALITY ... correct Power Factor and Harmonics problems!
-
It's Power Factor Correction (PFC) and Total Harmonics Distortion (THD)
-
PF displacement (leading/lagging) is between the voltage and the current
-
Harmonics voltage and current waveform distortion from non-linear loads
-
MPTS corrects PF/THD with mathematical algorithms & a 4Mb microchip
-
Post MPTS installation, all the PFC capacitor banks could be removed
![image.png](https://static.wixstatic.com/media/c78f87_ef281b9b06c44d37aa9f7e8af09a8be2~mv2.png/v1/fill/w_371,h_160,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
![image.png](https://static.wixstatic.com/media/c78f87_5226d1b4fbb2459e96d77cb50a48ad6d~mv2.png/v1/crop/x_0,y_0,w_576,h_304/fill/w_303,h_160,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
ENERGY EFFICIENCY ... when PF is close to 1.0 then KVA = KW ...
Power Factor 0.95 - 0.99 w/ MPTS
![image.png](https://static.wixstatic.com/media/c78f87_52c7d48885a444e5921e07d61a425119~mv2.png/v1/fill/w_675,h_160,al_c,lg_1,q_85,enc_avif,quality_auto/image.png)
Power Factor 0.30 - 0.90 w/o MPTS
ENERGY CONSERVATION ... when peak demand KW drops 22%
![image.png](https://static.wixstatic.com/media/c78f87_1a5951ec93c140e3a2fa42c50046c2be~mv2.png/v1/fill/w_678,h_182,al_c,lg_1,q_85,enc_avif,quality_auto/image.png)
w/o MPTS
w/ MPTS
±40KW
±50KW
±90KW
±70KW
POWER MONITORING/ANALYSIS ... the meters don't lie ...
-
Real-time 24 x 7 KVA/KVAh, KVAr/KVArh, KW/KWh, PF per 3-phase
-
See the good and the bad i.e., before and after since MPTS install
-
Billing reconciliation ... compare billed to actual ... aka utility to MPTS
-
Energy/Business Management Systems (BMS/EMS) only read & report
-
MPTS reads & reports, then restores & reports ... +20,000 times/second
-
Trending is fundamental ... what's working, what is not looking good
Comparison
MPTS™ ... nothing else compares to its uniqueness!
![image.png](https://static.wixstatic.com/media/c78f87_b5a1190b68ee4809883d4f42b89a8575~mv2.png/v1/fill/w_358,h_132,al_c,q_85,usm_0.66_1.00_0.01,enc_avif,quality_auto/image.png)
PFC - Power Factor Correction
HPF - Harmonic Power Filters
UPS - Uninterruptible Power Supply
VFD - Variable Frequency Drive
MPTS - Maximum Power Transfer Solution
CAUSES and EFFECT
Adds load & capacitance & harmonics
Requires operational programming
Requires significant maintenance
Parasitic load on electrical networks
Interrupts power to the load when off
Reduces power consumption by 20%-40%
Increases useful life of connected equipment
Consumes less than 100W - electronic solution
Decreases service, repair, and maintenance costs
Decreases amps, kVA, kVAr, kVAh, kVArh, kW, kWh)
Increase facility wiring capacity from reduced current
Reduces heat on switchqear and total facility wiring
Works on balanced or unbalanced load conditions
Can be moved to different applications or loads
Decreases Total Harmonic Distortion (THD)
Standard models, capacities
Reduces carbon footprint
Improves Power Factor
Stabilizes all voltages
Improves power quality
Decreases capital costs
PFC
x
x
x
x
x
x
HPF
x
x
x
x
x
UPS
x
x
x
x
x
x
VFD
x
x
x
x
x
MPTS
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Why MPTS™ is a unique differentiator ...
Unique
What do the minimum power 4Mb microchips have to do with resolving Power Factor & Harmonics issues?
POWER FACTOR - Voltage and Current Waveform Displacement
Consultants/Engineers Q1: Where are the capacitors? Power Factor Correction = installed capacitor banks.
There are none. It's a solid-state electronics solution resolving reactive power with mathematical algorithms. .
Let's keep this simple ... a little science... all 5 x formulae below mean the same thing i.e. Power Factor (PF):
-
Energy Efficiency = Power Factor (PF)
-
True Power / Apparent Power = Power Factor (PF)
-
Active Power / Active Power + Reactive Power = Power Factor (PF)
-
KiloWatts / KiloWatts + KiloVolts-Amps Reactive = Power Factor (PF)
-
kW / kW + kVAr = Power Factor (PF)
If we could eliminate kVAr then kW / kW = PF = 1.0 (often referred to as unity) = perfect Energy Efficiency.
Attaining PF = 1.0 (unity) is virtually impossible, however 0.95 to 0.99 PF is perfectly acceptable to any utility.
MPTS™ is consistenly able to attain PF = 0.95 - 0.99 by virtually eliminating all of the kVAr (reactive power).
It aligns displacement between the supply electrical 50/60HZ voltage and current sinusoidal waveforms.
HARMONICS - Total Harmonics Distortion (THD) ... or Waveform Distortion
Power systems' THD implies higher peak currents, more heating, higher EMF and more motor core loss.
IEEE std. 519-2014 recommended practice & requirements for harmonic control in electric power systems.
MPTS™ introduced fully (IEEE std 519-2014) compliant 4 x Harmonics models in 2015 to its customer base.
Consider the Harmonics waveforms on the right:
-
Each harmonic is a power of the fundamental frequency e.g. 60 Hz
-
60/120/180/240/300 thru 3,000 = 1st/2nd/3rd/4th/5th/7th up to 50th
-
60-cycles per second each x 50-harmonics = 3,000 cycles per second
-
It needs the 4Mb chip power to read and report each of the 3,000 cps
-
Then the 4Mb chip power restores & reports all but the 1st harmonic
-
Restoration = Power Management vs. Power Reporting difference
CONCLUSION
The genius of MPTS™ lies in first recognizing it was Jacobi's Law of 1840 that needed to be solved and then programming the mathematical algorithms into the motherboard 4Mb microchips found in each unit This only took from 2001 to 2006. Development from fluorescent bulbs to higher-amperage lighting sub-panels through 2008; then onto even higher-amperage mechanical sub-panels and facility wide electrical networks by 2013; led to UL (Underwriters Laboratories) certification in March 2013.
MPTS™ is globally patented.
But it has not stopped there.
Artificial Intelligence (A.I.) incorporation has given MPTS™ the ability to predict certain electrical load effects and react to those in the most enegy efficient way, always ensuring power quality is first and foremost. There is much more to come on the A.I. front.
Finally, UL does not test and certify equipment then buy one to test and certify all vendor's electrical equipment unless it believes in its quality and performance ... proven these past 10years! Neither does NORAD, the North American Aerospace Defense Command ... considering it vitally strategic role.